1KD-FTV INTAKE > SERVICE DATA |
| Engine Condition | VSV Condition | Specified Condition |
| Normal engine speed | ON | Approximately 35 kPa (263 mmHg, 10.35 in.Hg) |
| 3,000 rpm or more | OFF | 0 kPs (0 mmHg, 0 in.Hg) |
| Tester Connection | Specified Condition |
| 1 - 2 | 33 to 39 Ω at 20°C (68°F) |
| 1 - Body ground 2 - Body ground | 1 MΩ or higher |
| Condition | Specified Condition |
| Engine speed (approximately 4,600 rpm) | 15 to 45 kPs (0.15 to 0.46 kgf*cm2, 2.1 to 6.5 psi) |
| Condition | Tester Connection | Specified Condition |
| ECM output voltage | T9-3 (VC (+)) - T9-1 (E2 (-)) | 4.5 to 5.5 V |
| Applied vacuum | - | - |
| -13.3 kPs (100 mmHg, 3.94 in.Hg) | E7-28 (PIM) - E8-28 (E2) | 0.1 to 0.4 V |
| -26.6 kPs (199 mmHg, 7.85 in.Hg) | 0.2 to 0.6 V | |
| -40 kPs (300 mmHg, 11.81 in.Hg) | 0.4 to 0.8 V | |
| Applied pressure | - | - |
| 19.6 kPs (0.20 mmHg, 2.84 in.Hg) | E7-28 (PIM) - E8-28 (E2) | 0.1 to 0.4 V |
| 39.2 kPs (0.40 mmHg, 5.69 in.Hg) | 0.4 to 0.7 V | |
| 58.8 kPs (0.60 mmHg, 8.53 in.Hg) | 0.7 to 1.0 V | |
| 78.5 kPs (0.80 mmHg, 11.4 in.Hg) | 1.0 to 1.3 V | |
| 98.0 kPs (1.00 mmHg, 14.2 in.Hg) | 1.3 to 1.6 V |
| Condition | Specified Condition |
| Maximum axial play of turbine shaft | 0.11 mm (0.0043 in.) |
| Maximum radial play of turbine shaft | 0.112 mm (0.0044 in.) |