1KD-FTV COOLING > SERVICE DATA



Thermostat:

Condition
Specified Condition
Valve opening temperature
80 to 84 °C (176 to 183°F)
Valve lift
10 mm (0.39 in.) or more at 95°C (203°F)


Radiator reservoir cap:

Item
Specified Condition
Standard value
(for brand-new cap)
93.3 to 122.7 kPa (0.95 to 1.25 kgf*cm2, 13.5 to 17.8 psi)
Minimum standard value
(after using cap)
78.5 kPa (0.8 kgf*cm2, 11.4 psi)