HEATED OXYGEN SENSOR (for Unleaded Gasoline Specification Vehicle) > INSPECTION
for Preparation
Click here
1. INSPECT HEATED OXYGEN SENSOR
Measure the resistance between terminals 1 (HT) and 2 (+B) of the sensor.
Standard resistance:
11 to 16 Ω at 20°C (68°F)
If the result is not as specified, replace the sensor.