BACK-UP LIGHT SWITCH > INSPECTION
for Preparation
Click here
1. INSPECT BACK-UP LIGHT SWITCH ASSEMBLY
Measure the resistance of the switch.
Standard:
Tester Connection
Switch Condition
Specified Condition
1 - 2
Pushed
Below 1 Ω
1 - 2
Not Pushed
10 kΩ or higher
If the result is not as specified, replace the switch assembly.