HEATED OXYGEN SENSOR (for Sensor 2) > ON-VEHICLE INSPECTION

for Preparation Click here



1. INSPECT HEATED OXYGEN SENSOR


A062378E11
  1. Using an ohmmeter, measure the resistance between the terminals.

    Standard resistance:
    Tester Connection
    Specified Condition
    1 (HT) - 2 (+B)
    11 to 16 Ω at 20°C (68°F)
    1 (HT) - 4 (E1)
    10 kΩ or higher

    If the resistance is not as specified, replace the sensor.