HEATED OXYGEN SENSOR (for Sensor 2) > REMOVAL

for Preparation Click here



1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

CAUTION:
Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to prevent airbag and seat belt pretensioner activation.



2. REMOVE HEATED OXYGEN SENSOR (for Bank 1 Sensor 2)


A112022E01
  1. Disconnect the sensor connector.

  1. Using SST, remove the sensor from the front exhaust pipe.

    SST
    09224-00010  



3. REMOVE HEATED OXYGEN SENSOR (for Bank 2 Sensor 2)


A112020E01
  1. Disconnect the sensor connector.

  1. Using SST, remove the sensor from the front exhaust pipe.

    SST
    09224-00010