HEATED OXYGEN SENSOR (for Sensor 2) > INSTALLATION

for Preparation Click here



1. INSTALL HEATED OXYGEN SENSOR (for Bank 1 Sensor 2)


A112023E03
  1. Using SST, install the sensor to the front exhaust pipe.

    SST
    09224-00010  

    Torque:
    40 N*m{ 408 kgf*cm , 30 ft.*lbf } for use with SST
    44 N*m{ 449 kgf*cm , 32 ft.*lbf } for use without SST

    HINT:
    Use a torque wrench with a fulcrum length of 30 cm (11.81 in.).

  1. Connect the sensor connector.



2. INSTALL HEATED OXYGEN SENSOR (for Bank 2 Sensor 2)


A112021E03
  1. Using SST, install the sensor to the front exhaust pipe.

    SST
    09224-00010  

    Torque:
    40 N*m{ 408 kgf*cm , 30 ft.*lbf } for use with SST
    44 N*m{ 449 kgf*cm , 32 ft.*lbf } for use without SST

    HINT:
    Use a torque wrench with a fulcrum length of 30 cm (11.81 in.).

  1. Connect the sensor connector.



3. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL


4. PERFORM INITIALIZATION
  1. Perform initialization (Click here).

    NOTICE:
    Certain systems need to be initialized after disconnecting and reconnecting the cable from the negative (-) battery terminal.