AIR FUEL RATIO SENSOR (for Sensor 1) > INSTALLATION

for Preparation Click here



1. INSTALL AIR FUEL RATIO SENSOR (for Bank 1 Sensor 1)


A112026E01
  1. Using SST, install the sensor to the exhaust manifold.

    SST
    09224-00010  

    Torque:
    40 N*m{ 408 kgf*cm , 30 ft.*lbf } for use with SST
    44 N*m{ 449 kgf*cm , 32 ft.*lbf } for use without SST

    HINT:
    Use a torque wrench with a fulcrum length of 30 cm (11.81 in.).

  1. Connect the sensor connector.



2. INSTALL AIR FUEL RATIO SENSOR (for Bank 2 Sensor 1)


A112028E01
SST
09224-00010  
  1. Using SST, install the sensor to the exhaust manifold.

    Torque:
    40 N*m{ 408 kgf*cm , 30 ft.*lbf } for use with SST
    44 N*m{ 449 kgf*cm , 32 ft.*lbf } for use without SST

    Use a torque wrench with a fulcrum length of 30 cm (11.81 in.).

  1. Connect the sensor connector.



3. INSTALL V-BANK COVER
  1. Install the cover with the 2 nuts.

    Torque:
    7.5 N*m{ 76.5 kgf*cm , 66 in.*lbf }



4. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL


5. PERFORM INITIALIZATION
  1. Perform initialization (Click here).

    NOTICE:
    Certain systems need to be initialized after disconnecting and reconnecting the cable from the negative (-) battery terminal.