CANISTER > INSPECTION

for Preparation Click here



1. INSPECT CANISTER


A099534E04
  1. Inspect operation of the canister.

    OK:
    Checking Method
    Result
    Close port B and C, then apply vacuum to port A
    No leak
    Close port C, then blow air into port A
    Air flows from port B
    Blow air into port A
    Air flows from both port B and C

    If the result is not as specified, replace the canister.