HAZARD WARNING SWITCH > INSPECTION |
| 1. INSPECT HAZARD WARNING SWITCH ASSEMBLY |
![]() |
Measure the resistance of the switch.
| Tester Connection | Switch Condition | Specified Condition |
| 2 (E) - 4 (TB) | OFF | 10 kΩ or higher |
| 2 (E) - 4 (TB) | ON | Below 1 Ω |
Check illumination operation.
Connect the battery's positive (+) lead to terminal 8 and negative (-) lead to terminal 9. Then check that the Bulb illuminates.