HAZARD WARNING SWITCH > INSPECTION

for Preparation Click here



1. INSPECT HAZARD WARNING SWITCH ASSEMBLY


    B059807E02
  1. Measure the resistance of the switch.
    Standard resistance: 
    Tester Connection
    Switch Condition
    Specified Condition
    2 (E) - 4 (TB)
    OFF
    10 kΩ or higher
    2 (E) - 4 (TB)
    ON
    Below 1 Ω
    If the result is not as specified, replace the switch assembly.

  1. Check illumination operation.

    1. Connect the battery's positive (+) lead to terminal 8 and negative (-) lead to terminal 9. Then check that the Bulb illuminates.

      OK:
      Bulb illuminates.

      If the result is not as specified, replace the switch assembly.