THERMOSTAT > INSPECTION |
| 1. INSPECT WATER INLET HOUSING WITH THERMOSTAT |
![]() |
![]() |
Immerse the thermostat in the water, then heat the water gradually.
Check the valve opening temperature of the thermostat.
![]() |
Check the valve lift.
Check that the valve is fully closed when the thermostat is at low temperature (below 40°C (104°F)).
If not fully closed, replace the water inlet housing with thermostat.