THERMOSTAT > INSTALLATION |
| 1. INSTALL THERMOSTAT |
![]() |
Install a new gasket to the thermostat.
Insert the thermostat into the cylinder block with the jiggle valve facing straight upward.
| 2. INSTALL WATER INLET |
![]() |
Install the inlet with the 3 bolts.
| 3. CONNECT RADIATOR HOSE INLET |
| 4. INSTALL AIR CLEANER ASSEMBLY |
![]() |
Connect the air cleaner hose.
Install the air cleaner with the 2 bolts.
Tighten the clamp.
Install the clamp and connect the IAT connector.
Connect the ventilation hose.
Slide the clamp to the connection of the hose.
| 5. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL |
| 6. ADD ENGINE COOLANT |
Tighten the radiator drain cock plug by hand.
Tighten the cylinder block drain cock plug.
![]() |
Fill the radiator with TOYOTA Super Long Life Coolant (SLLC) to the reservoir tank's B line.
Press the inlet and outlet radiator hoses several times by hand, and then check the level of the coolant.
If the coolant level drops below the B line, add TOYOTA SLLC to the B line.
Install the radiator reservoir cap.
![]() |
Using a wrench, install the vent plug.
Bleed air from the cooling system.
Warm up the engine until the thermostat opens. While the thermostat is open, circulate the coolant for several minutes.
Maintain the engine speed at 2,000 to 2,500 rpm.
Press the inlet and outlet radiator hoses several times by hand to bleed air.
Stop the engine and wait until the coolant cools down to ambient temperature.
![]() |
After the coolant cools down, check that the coolant level is at the F line.
If the coolant level is below the F line, add TOYOTA SLLC to the F line.
| 7. CHECK FOR ENGINE COOLANT LEAKS |
Check for the engine coolant leaks (Click here).
| 8. INSTALL NO. 1 ENGINE UNDER COVER |
Install the cover with the 4 bolts.
| 9. PERFORM INITIALIZATION |
Perform initialization (Click here).