AIR PUMP (for Unleaded Gasoline Specification Vehicle) > INSTALLATION

for Preparation Click here



1. INSTALL AIR PUMP ASSEMBLY


    A110284E01
  1. Install the pump to the bracket with air pump insulator.



2. CONNECT NO. 3 AIR HOSE


    A110285E01
  1. Connect the No. 3 hose to the pump.



3. CONNECT NO. 2 AIR HOSE
  1. Connect the No. 2 hose to the pump.

  1. Secure the No. 2 hose with the clamp.

  1. Clamp the No. 2 hose and wire harness with the clamp.



4. INSTALL AIR PUMP COVER


    A110286
  1. Install the cover to the bracket with the 3 clips.



5. INSTALL AIR PUMP PIPE


    A110287
  1. Install the inlet pipe to the body panel with the bolt.

    Torque:
    13 N*m{ 133 kgf*cm , 10 ft.*lbf }



6. INSTALL AIR PUMP ASSEMBLY WITH BRACKET


    A110288E02
  1. Install the pump with bracket to the body panel with the 3 bolts.

    Torque:
    13 N*m{ 133 kgf*cm , 10 ft.*lbf }

    HINT:
    Attach the bracket's protrusion to the body's hole.

  1. Connect the No. 2 and No. 3 hoses to the inlet pipe.

    HINT:
    Connect the No. 2 air hose to the pipe connected to the air switching valve.

  1. Secure the No. 2 hose with the clamp.



    A110289
  1. Install the 2 claws to the inlet pipe and body panel.

  1. Connect the connector.



7. INSTALL FRONT FENDER APRON SEAL UPPER
  1. Install the apron seal with the 6 clips.



8. CONNECT NO. 4 AIR HOSE


    A110280E01
  1. Connect the No. 4 hose to the air switching valve and inlet pipe.

  1. Secure the hose with the 2 clamps.

  1. Clamp the hose with the clamp.



9. INSTALL AIR PUMP INLET
  1. Connect the hose to the inlet pipe.

  1. Install the pump inlet to the radiator tank upper with the bolt.

    Torque:
    8.5 N*m{ 87 kgf*cm , 75 in.*lbf }



10. INSTALL AIR CLEANER ASSEMBLY


    A099521E01
  1. Connect the air cleaner hose.

  1. Install the air cleaner with the 2 bolts.

    Torque:
    14 N*m{ 143 kgf*cm , 10 ft.*lbf }

  1. Tighten the hose clamp.

    Torque:
    4.0 N*m{ 41 kgf*cm , 35 in.*lbf }

  1. Connect the MAF meter connector.



11. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL


12. PERFORM INITIALIZATION
  1. Perform initialization (Click here).

    CAUTION:
    Certain systems need to be initialized after disconnecting and reconnecting the cable from the negative (-) battery terminal.