HEATED OXYGEN SENSOR > INSPECTION

for Preparation Click here



1. INSPECT HEATED OXYGEN SENSOR


    A112088E01
  1. Measure the resistance between terminals 1 (HT) and 2 (+B) of the sensor.

    Standard resistance:
    11 to 16 Ω at 20°C (68°F)

    If the result is not as specified, replace the heated oxygen sensor.