CRANKSHAFT POSITION SENSOR > INSPECTION

for Preparation Click here



1. INSPECT CRANKSHAFT POSITION SENSOR


E034870E01
  1. Measure the resistance between the terminals.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    Approx. 20°C (68°F)
    1,850 to 2,450 Ω

    1. If the result is not as specified, replace the sensor.