GENERATOR > REMOVAL |
| 1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL |
| 2. REMOVE INTAKE AIR CONNECTOR AND AIR CLEANER ASSEMBLY |
![]() |
Disconnect the vacuum hose.
Disconnect the No. 2 ventilation hose.
Disconnect the MAF meter connector and wire harness clamps.
Loosen the hose clamp and remove the 4 bolts, air cleaner and intake air connector assembly.
| 3. REMOVE DRIVE BELT |
![]() |
Use the hexagon-shaped part indicated by the arrow in the illustration to move the tensioner pulley downward and decrease the tension in the drive belt. Then remove the drive belt.
| 4. REMOVE GENERATOR ASSEMBLY |
![]() |
Remove the nut, bolt and generator wire.
Disconnect the generator connector.
Remove the 2 bolts and generator.