AIR CONDITIONING CONTROL ASSEMBLY > INSPECTION

for Preparation Click here



1. INSPECT AIR CONDITIONING CONTROL ASSEMBLY


    I044308E01
  1. Measure the resistance of the blower switch.

    Standard resistance:
    Switch Condition
    Tester Connection
    Specified Condition
    OFF
    1 - 2 - 4 - 5 - 6
    10 kΩ or higher
    LO
    5 - 6
    Below 1 Ω
    LO - M1
    2 - 5 - 6
    Below 1 Ω
    M1
    2 - 5 - 6
    Below 1 Ω
    M1 - M2
    1 - 2 - 5 - 6
    Below 1 Ω
    M2
    1 - 5 - 6
    Below 1 Ω
    M2 - HI
    1 - 4 - 5 - 6
    Below 1 Ω
    HI
    4 - 5 - 6
    Below 1 Ω

    If the result is not as specified, replace the A/C control.

  1. Inspect illuminations.

    1. Connect the battery's positive (+) lead to terminal 8 and negative (-) lead to terminal 3. Check that the bulbs illuminate.
      If a bulb does not illuminate, replace it.