SFI SYSTEM > MIL Circuit |

| MIL remains illuminated | Start inspection from step 1 |
| MIL not illuminated | Start inspection from step 3 |
| 1.CHECK THAT MIL IS ILLUMINATED |
Troubleshoot each trouble symptom in accordance with the chart below.
| Condition | Proceed to |
| MIL remains illuminated | A |
| MIL not illuminated | B |
|
| ||||
| A | |
| 2.CHECK WHETHER MIL TURNS OFF |
Connect the intelligent tester to the DLC3.
Turn the ignition switch ON and turn the tester ON.
Check whether any DTCs have been stored. Write them down if necessary.
Clear DTCs (Click here).
Check if the MIL turns OFF.
|
| ||||
| NG | |
| 3.CHECK WIRE HARNESS (CHECK FOR SHORT IN WIRE HARNESS) |
![]() |
Disconnect the E13 ECM connector.
Turn the ignition switch ON.
Check the MIL is not illuminated.
|
| ||||
| NG | ||
| ||
| 4.CHECK THAT MIL IS ILLUMINATED |
Check if the MIL is illuminated when the ignition switch is turned ON.
|
| ||||
| NG | |
| 5.INSPECT COMBINATION METER ASSEMBLY (MIL CIRCUIT) |
See the combination meter troubleshooting procedures (Click here).
|
| ||||
| OK | ||
| ||