CAMSHAFT POSITION SENSOR > REMOVAL

for Preparation Click here



1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

CAUTION:
Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to prevent airbag activation.



2. REMOVE CAMSHAFT POSITION SENSOR


    A099146E01
  1. Disconnect the sensor connector.

  1. Remove the bolt and sensor.