CAMSHAFT TIMING OIL CONTROL VALVE ASSEMBLY > REMOVAL |
| 1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL |
| 2. REMOVE CAMSHAFT TIMING OIL CONTROL VALVE ASSEMBLY |
![]() |
Disconnect the oil control valve connector.
Remove the bolt and oil control valve.
Remove the O-ring from the oil control valve.