CHECK AT A/C-ECU TERMINALS




Terminal No.
Check items
Check conditions
Normal conditions
1
ILL power supply
Lighting switch: ON
System voltage
2
A/C pressure sensor input
Refer to .
Refer to .
3
Earth
Always
Continuity exists.
4
Air mixing damper control motor and potentiometer (MAX HOT)
When the damper flaps are moving to the MAX COOL position.
1.0 V or less
When the damper flaps are moving to the MAX HOT position.
System voltage
5
Air mix damper motor (MAX COOL)
When the damper flaps are moving to the MAX COOL position.
System voltage
When the damper flaps are moving to the MAX HOT position.
1.0 V or less
6, 7
-
-
-
8
Rear window defogger relay
Rear window defogger relay: ON
1.0 V or less
9
Outside/inside air selection damper motor (Fresh air position)
When setting the fresh air position
1.0 V or less
When setting the air recirculation position
System voltage
10
Illumination earth
Always
Continuity exists.
11
-
-
-
12
Sensors and potentiometers earth
Always
1.0 V or less
13
Sensor power supply:
Ignition switch: IG2
5 V
14
Input from the air thermo sensor
Sensor temperature: 25°C (4kΩ)
2.1 - 2.7 V
15
Input from air mixing damper control motor potentiometer
MAX HOT position.
0.97 - 1.03 V
16
A/C pressure sensor power supply
Always
System voltage
17
outside/inside air selection damper control motor (inside)
When the damper is moved to the inside air recirculation position
1.0 V or less
When the damper is moved to the outside air inside air intake position
System voltage
18
IG2 power supply
Ignition switch: ON
System voltage