INSPECTION




RESISTOR CHECK



Use an ohmmeter to measure the resistance between the terminals. Check that the measured value is at the standard value.
Standard value:
Measurement terminal
Standard value (Ω)
Between terminals 3 and 4 (LO)
2.15
Between terminals 2 and 4 (ML)
0.74
Between terminals 1 and 4 (MH)
0.27

BLOWER FAN AND MOTOR CHECK



When battery voltage is applied between the terminals, check that the motor operates. Also, check that there is no abnormal noise.

OUTSIDE/INSIDE AIR SELECTION DAMPER CONTROL MOTOR CHECK



caution Cut off the battery voltage when the damper is in the outside/inside air position.
Lever position
Battery connection
Lever operation
At the inside position

  • Connect terminal 1 to the positive battery terminal
  • Connect terminal 5 to the negative battery terminal

The lever moves from the inside position to the outside position
At the outside position

  • Connect terminal 1 to the positive battery terminal
  • Connect terminal 4 to the negative battery terminal

The lever moves from the outside position to the inside position