REMOVAL AND INSTALLATION <COLT (Vehicles without side air dam)>







Removal

>>A<<
1.
Protector film

INSTALLATION SERVICE POINT



>>A<< PROTECTOR FILM INSTALLATION


1. Installation position


2.
caution
  • The ambient temperature should be 20 to 38°C. Ensure that the working area is clean.
  • If ambient temperature is less than 20°C, heat the protector film and application surface to a temperature of 20 to 30°C.
  • Be careful that air bubbles are not formed under the protector film.
Installation procedure
(1) Use Parts Cleaner (MZ100387 or equivalent) to degrease the protector film application surface.
(2) Remove backing paper from the protector film, and apply it to the specified position.