ACTUATOR




HYDRAULIC UNIT


The hydraulic unit incorporates the ABS control, TCL control and ASC control. The cut valve, pressure relief valve, suction valve, suction damper, and pressure sensor have been added to the unit for the TCL control and ASC control.
note For the internal hydraulic circuit of the hydraulic unit, refer to .

TCL/ASC INDICATOR LAMP


The TCL/ASC system illuminates or flashes the TCL/ASC indicator lamp in the following operation patterns, and informs the driver of the TCL/ASC system status.

note *: The ASC functions at speeds of apploximately 10 km/h or higher.

TCL/ASC indicator lamp illumination and flashing patterns
State
TCL/ASC indicator lamp
Normal
Normal
-
ASC operated
Flashing (3 Hz)
TCL operated
Flashing (3 Hz)
Abnormal
ASC malfunction
Illuminates
TCL malfunction
Illuminates
M.U.T.-III connection
Actuator operated
Illuminates