Automated manual transmission control relay check



1.Removal the automated manual transmission control relay.
2.Use the jumper leads to connect automated manual transmission control relay terminal 2 to the negative battery terminal and terminal 1 to the positive battery terminal.
3.Check the continuity between automated manual transmission control relay connector terminals 3 and 4 while alternately connecting and disconnecting the jumper leads from the battery terminals.
Jumper leads
Continuity between terminals 3 and 4
Connected
Continuity (Less than 2 Ω)
Disconnected
Open circuit
4.If there is a malfunction, replace the automated manual transmission control relay.