1.Remove the ventilation hose from the PCV valve.
|
|
|
2.Remove the PCV valve from the rocker cover.
|
|
|
3.Reinstall the PCV valve at the ventilation hose.
|
|
|
4.Start the engine and run at idle.
|



|
5.Place a finger at the opening of the PCV valve and check that vacuum of the inlet manifold
is felt.
| note |
At this moment, the plunger in the PCV valve moves back and forth.
|
6.If vacuum is not felt, clean the PCV valve or replace it. 7.In case of 3A9 and 4A9 engine only, apply a small amount of new engine oil to the
O-ring on the positive crankcase ventilation valve, and tighten to the specified torque. Standard value: 2.5 ± 0.4 N·m
|