1.Immerse the thermostat in water, and heat the water while stirring. Check the thermostat
valve opening temperature. Standard value: Valve opening temperature:
<134, 135> 82 ± 2 °C <3A9, 4A9> 87 ± 2 °C <4G1> 82 ± 1.5 °C
|

|
2.Check that the amount of valve lift is at the standard value when the water is at the
full-opening temperature.
| note |
Measure the valve height when the thermostat is fully closed, and use this measurement
to compare the valve height when the thermostat is fully open.
|
Standard value:
Full-opening temperature: 95°C Amount of valve lift:
<Except for 4G1> 8 mm or more <4G1> 8.5 mm or more
|