| note | Monitoring stops after fuel has been shut off for 64 seconds or more. |
DIAGNOSIS PROCEDURE |
STEP 1. M.U.T.-III data list |
Q.
Is the check result normal?
|
Intermittent malfunction (Refer to GROUP 00 - How to Use Troubleshooting/Inspection
Service Points - How to Cope with Intermittent Malfunctions ). |
|
Go to Step 2 . |
|
STEP 2. Replace the oxygen sensor (rear) |
|
Q.
Is the diagnosis code set?
|
Check oxygen sensor (rear) system (Refer to Code No. P0136 ). |
|
Check end. |
|