1.Disconnect the oil control valve connector.
| caution |
To prevent the coil from burning, keep the duration of the voltage
application as short as possible.
|
2.Apply battery voltage to the terminals of the connector at the oil control valve,
and make sure the oil control valve makes a clicking sound.
|
|
|
1.Disconnect the oil control valve connector.
|
|
|
2.Measure the resistance between the terminals of the connector at the oil control valve.
|
|
|
Standard value: 6.9 - 7.9 Ω (at 20°C)
|
|
|
3.If resistance is outside the standard value, replace the oil control valve.
|