1.Disconnect the accelerator pedal position sensor connector. 2.Measure resistance between terminal No. 2 (main power supply) and No. 4 (main earth) of the sensor connector. Standard value: 1.1 -
2.4 kΩ
(at 20°C) 3.Measure resistance between terminal No. 1 (sub power supply) and terminal No. 5 (sub earth) of the sensor connector Standard value: 0.8 -
1.7 kΩ
(at 20°C) 4.Measure resistance between terminal No. 2 (main power supply) and No. 3 (main output) as well as between terminal No. 1 (sub power supply) and No. 6 (sub output) of the sensor connector.
Normal condition:
Depress the accelerator pedal slowly.
|
Resistance value changes in accordance with the accelerator pedal depression smoothly.
|
5.If not within the standard value, or resistance value does not change smoothly, replace the accelerator pedal assembly.
|