1.Disconnect the manifold absolute pressure sensor connector. 2.Measure resistance between terminals No. 3 and No. 4. Standard value:
13 -
17 kΩ
(at -20°C) 5.3 -
6.7 kΩ
(at 0°C) 2.3 -
3.0 kΩ
(at 20°C) 1.0 -
1.5 kΩ
(at 40°C) 0.56 -
0.66 kΩ
(at 60°C) 0.30 -
0.36 kΩ
(at 80°C)
3.Remove the manifold absolute pressure sensor
|

|
4.Measure resistance while heating the sensor using a hair drier.
Normal condition:
Temperature (°C)
|
Resistance (kΩ)
|
Higher
|
Smaller
|
5.If the value deviates from the standard value or the resistance remains unchanged, replace the manifold absolute pressure sensor assembly. 6.Install the manifold absolute pressure sensor and tighten it to the specified torque. Tightening torque: 6.0 ±
0.5 N·m
|