INTAKE AIR TEMPERATURE (IAT) SENSOR INSPECTION [ZJ, Z6]
B3E014018840W06
-
Note
-
• Before performing the following inspection, make sure to follow the procedure as indicated in the troubleshooting flowchart. (See Troubleshooting Procedure.)
Resistance Inspection
1. Disconnect the MAF/IAT sensor connector.
2. Verify that the resistance between terminals D and E is within the specification.
-
• If not within the specification, replace the MAF/IAT sensor. (See MASS AIR FLOW (MAF)/INTAKE AIR TEMPERATURE (IAT) SENSOR REMOVAL/INSTALLATION [ZJ, Z6].)
-
• If the monitor item condition/specification (reference) is not within the specification, even though there is no malfunction, perform the "Circuit Open/Short Inspection".
-
IAT sensor resistance
|
Ambient temperature (°C {°F})
|
Resistance (kilohm)
|
|
-20 {-4}
|
13.618.4
|
|
20 {68}
|
2.212.69
|
|
60 {140}
|
0.4930.667
|
IAT sensor characteristics graph (reference)
Circuit Open/Short Inspection
1. Remove the PCM connector cover.
2. Disconnect the PCM connector. (See INTAKE-AIR SYSTEM REMOVAL/INSTALLATION [ZJ, Z6].)
3. Inspect the following wiring harness for open or short circuit (continuity check).
Open circuit
-
• If there is no continuity, there is an open circuit. Repair or replace the wiring harness.
-
- MAF/IAT sensor terminal D and PCM terminal 2AQ
-
- MAF/IAT sensor terminal E and PCM terminal 2AY
Short circuit
-
• If there is continuity, there is a short circuit. Repair or replace the wiring harness.
-
- MAF/IAT sensor terminal D and power supply
-
- MAF/IAT sensor terminal D and body GND
-
- MAF/IAT sensor terminal E and power supply