Blower Unit Removal and Installation
Blower Unit Removal and Installation
NOTE: LHD type is shown, RHD type is symmetrical.| 1. | Remove the passenger's dashboard under cover and the inner glove box. |
| 2. | Disconnect the recirculation control cable from the recirculation control linkage. |
| 3. | Disconnect the connector (A) from the blower motor, then remove the mounting bolt, the self-tapping screws, and the bracket (B).
9.8 N·m (1.0 kgf·m, 7.2 lbf·ft) |
| 4. | Remove the clip (A). Remove the mounting bolt, the screws, and the bracket (B). Remove the connector clip (C). Remove the self-tapping screws and the blower unit (D).
9.8 N·m (1.0 kgf·m, 7.2 lbf·ft) |
| 5. | Install the unit in the reverse order of removal. Make sure that there is no air leakage. |