- A/C PRESSURE SWITCH
(Triple function)
When the refrigerant is below 196kPa (2.0 kgf/cm2, 28 psi) or above 3,140 kPa (32 kgf/cm2, 455 psi), the A/C pressure switch opens the circuit to the A/C switch and stops the air conditioning to protect the compressor.
When the refrigerant is above 1,520 kPa (15.5 kgf/cm2, 220 psi), the A/C pressure switch switches the radiator and condenser fans to high speed.
- EXPANSION VALVE
(Meters the required amount of refrigerant into the evaporator)
- BLOWER FAN
- EVAPORATOR
(Absorption of heat)
- EVAPORATOR TEMPERATURE SENSOR
- RELIEF VALVE
(Relieves pressure at the compressor when the pressure is too high)
- COMPRESSOR
(Suction and compression)
- HIGH PRESSURE VAPOUR
- HIGH PRESSURE LIQUID
- LOW PRESSURE LIQUID
- LOW PRESSURE VAPOUR
- CONDENSER
(Radiation of heat)
- RECEIVER/DRYER
(Traps debris, and removes moisture)
|