Diesel Engine Management System

DTC Troubleshooting (cont'd)

11-99  

DTC P1092: Rail Pressure (RP) Control Valve Circuit Short

  1. Check the ''On Board Diagnostic (OBD) System Check''.

Was the ''OBD System Check'' performed?

YES – Go to step 2.

NO – Go to OBD System Check.

  1. Check the DTC.

Are there any other DTCs (beside DTC P1092) being output?

YES – Go to relevant DTC chart.

NO – Go to step 3.

  1. Check for the following conditions:
  • Damaged the fuel metering unit.

Is a problem found?

YES – Repair as necessary (Replace the fuel supply pump).

NO – Go to step 4.

  1. Turn the ignition switch OFF.
  1. Disconnect ECM connector.
  1. Check the fuel metering unit circuit for short.

Is a problem found?

YES – Repair the fuel metering unit circuit.

NO – Go to step 7.

  1. Measure the resistance of fuel metering unit as below.

Is the resistance value 2.5 – 3.2 ohms (At room temperature)?

YES – Substitute a known-good ECM and recheck. If symptom/indication goes away, replace the original ECM.

NO – Replace the supply pump.

NOTICE

The battery power supply short circuit to 5 V power supply damages the ECM.