Diesel Engine Management System
|
11-97 |
Is a problem found? YES – Repair the RP sensor signal or +5 V circuit. NO – Go to step 11.
Is about 5 V indicated? YES – Substitute a known-good ECM and recheck. If symptom/indication goes away, replace the original ECM. NO – Go to step 12.
Is there 0.9 – 1.3 ohms (At room temperature; about 20°C (68°F))? YES – Go to step 14. NO – Replace the RP sensor. |
Was a problem completed ohm? YES – System is OK. NO – Replace the supply pump.
The battery power supply short circuit to 5 V power supply damages the ECM. |