Diesel Engine Management System
|
11-58 |
Wire side of female terminals RP sensor 3P connector
JUMPER WIRE
Is a problem found? YES – Repair the RP sensor ground circuit. NO – Go to step 13.
Is there 0.9 – 1.3 kohms YES – Substitute a known-good ECM and recheck. If symptom/indication goes away, replace the original ECM. NO – Replace the RP sensor.
The battery power supply short circuit to 5 V power supply damages the ECM. |