Diesel Engine Management System
|
11-101 |
Is there about 0.9 – 1.3 Kohms? YES – Go to step 12. NO – Replace the RP sensor.
Is there 1 V indicated? YES – Intermittent failure, system is OK at this time. Check for poor connections or loose wires at the RP sensor and at the ECM. NO – Replace the RP sensor. |
Was a problem completed? YES – System is OK. NO – Replace the supply pump.
The battery power supply short circuit to 5 V power supply damages the ECM. |