- Drain the engine coolant (see page 10-6).
- Remove the expansion tank hoses, then remove the expansion tank.

- Install the expansion tank in the reverse order of removal.
- Refill the radiator with engine coolant and bleed air from the cooling system with the heater valve open (see page 10-6).
|  |
- Disconnect the 2P connectors from the radiator fan motor and condenser fan motor.

- Test the motor by connecting battery power to the B terminal and ground to the A terminal.
- If the motor fails to run or does not run smoothly, replace it.
|