Standards and Service Limits

CVT and Differential

2-15  

Item Measurement Qualification Standard or New Service Limit
CVT Fluid Capacity Use genuine Honda ATF-Z1 For fluid change: 3.1 l (3.3 US qt, 2.7 lmp qt)

For overhaul: 5.6 l (5.9 US qt, 4.9 lmp qt)

Hydraulic pressure Forward clutch pressure At 1,500 rpm (min-1) in position 1.4-1.75 MPa

(14.3-17.8 kgf/cm2, 203-253 psi)

Reverse brake pressure At 1,500 rpm (min-1) in position 1.4-1.75 MPa

(14.3-17.8 kgf/cm2, 203-253 psi)

Drive pulley pressure At 1,500 rpm (min-1) in position 0.2-0.7 MPa

(2.0-7.1 kgf/cm2, 28-101 psi)

Driven pulley pressure At 1,500 rpm (min-1) in position 1.5-2.3 MPa

(15.3-23.5 kgf/cm2, 218-334 psi)

Lubrication pressure At 3,000 rpm (min-1) in position Above 0.2 MPa

(Above 0.2 kgf/cm2, 30 psi)

Torque converter Stall speed

Check with vehicle on level ground

In position 2,500 rpm (min-1) 2,350-2,650 rpm (min-1)
In , and positions 2,800 rpm (min-1) 2,600-2,900 rpm (min-1)
ATF pump ATF pump drive gear shaft O.D.   9.98-9.99 mm (0.3929-0.3933 in.) When worn or damaged
ATF pump driven gear shaft O.D.   9.98-9.99 mm (0.3929-0.3933 in.) When worn or damaged
ATF pump body bushing I.D. Drive gear shaft 10.0-10.015 mm (0.3937-0.3944 in.) When worn or damaged
Driven gear shaft 10.0-10.015 mm (0.3937-0.3944 in.) When worn or damaged
ATF pump gear side clearance   0.015-0.035 mm (0.0006-0.0014 in.) -
ATF pump gear-to-body clearance Drive gear 0.035-0.0505 mm (0.0014-0.0020 in.) -
Driven gear 0.035-0.0505 mm (0.0014-0.0020 in.) -

aaa