Honda Accord ESM 2003 · Service Manual Service Manual 2003

CMP Pulse Plate A Replacement

CMP Pulse Plate A Replacement

1.Remove the cylinder head cover.

2.Hold the camshaft with an open-end wrench, then loosen the bolt.

SDA3EA0A14616716091KBAD01

3.Remove the camshaft position (CMP) pulse plate A.

SDA3EA0A14616716091KBAD0214 x 1.0 mm
39 N·m
(4.0 kgf·m, 29 lbf·ft)
Apply engine oil to the
bolt threads.

4.Install the CMP pulse plate A in the reverse order of removal.