Mode Control Motor Replacement

NOTE: LHD type is shown, RHD type is symmetrical.

1.Open the grove box. Remove the damper from the glove box, then let the glove box hang down

2.Remove the relays from the bracket.

3.Disconnect the 7P connector (A) from the mode control motor (B). Remove the self-tapping screws and the mode control motor from the heater unit.

4.Install the motor in the reverse order of removal. After installation, make sure the motor runs smoothly.