A/T Interlock System - Shift Lock System Circuit Troubleshooting

  1. Measure the voltage between transmission range switch connector terminals No. 2 and No. 5.
Is there more than 5 V?
YES -
Go to Step 31 .
NO -
Go to Step 25 .
  1. Turn the ignition switch to LOCK (0).
  1. Jump the SCS line with the HDS.
  1. Disconnect PCM connector B (49P).