DLC Circuit Troubleshooting
Check for continuity between PGM-FI main relay 1 4P connector terminal No. 2 and ECM/PCM connector terminal A9.
Is there continuity?
YES
-
Go to
Step 71
.
NO
-
Repair open in the wire between the ECM/PCM (A9) and PGM-FI main relay 1.■
Test PGM-FI main relay 1.
Is PGM-FI main relay 1 OK?
YES
-
Go to
Step 72
.
NO
-
Replace PGM-FI main relay 1 .■
Disconnect ECM/PCM connector B (49P).