DTC Troubleshooting: P0977 (8)
Check for continuity between PCM connector terminal B11 and shift solenoid wire harness connector terminal No. 2.
Is there continuity?
YES
-
Go to
Step 14
.
NO
-
Repair open in the wire between PCM connector terminal B11 and the shift solenoid wire harness connector, then go to
Step 16
.