Remove the motor cable (A).
-
Check the hold-in coil for continuity between the S terminal and the armature housing (ground). There should be continuity.
-
Check the pull-in coil for continuity between the S terminal and M terminal. There should be continuity.
-
If there is continuity, the solenoid is OK.
-
If there is no continuity, replace the solenoid.
-
Install the motor cable.
-
|
|