Brush Spring Inspection
-
Insert the brush (A) into the brush holder, and bring the brush into contact with the commutator, then attach a spring scale (B) to the spring (C). Measure the spring tension at the moment the spring lifts off the brush.
|
Spring Tension:
|
13.7−17.7 N (1.40−1.80 kgf, 3.09−3.97 lbf)
|
|
|