Check the pump housing-to-outer rotor radial clearance between the outer rotor (A) and the pump housing (B). If the pump housing-to-outer rotor radial clearance exceeds the service limit, replace the oil pump assembly.
Pump Housing-to-Outer Rotor Radial Clearance
|
Standard (New):
|
0.100−0.175 mm (0.0039−0.0069 in.)
|
|
Service Limit:
|
0.20 mm (0.008 in.)
|
-
Inspect both rotors and the pump housing for scoring or other damage. Replace the parts, if necessary.
-
Apply liquid thread lock to the pump housing screws, then install the oil pump cover.
-
Check that the oil pump turns freely.
|
|