F-CAN Circuit Troubleshooting

  1. Check for continuity between EPS control unit connector D (28P) terminal No. 15 and body ground.
Is there continuity?
YES -
Go to Step 16 .
NO -
Repair open in the wire between the ECM/PCM (A37) and the EPS control unit.■
  1. Reconnect the gauge control module 32P connector.