DLC Circuit Troubleshooting
Check for continuity between PGM-FI main relay 1 4P connector terminal No. 3 and ECM/PCM connector terminal A6.
Is there continuity?
YES
-
Test PGM-FI main relay 1.
If the relay is OK,
update the ECM/PCM if it does not have the latest software,
or
substitute a known-good ECM/PCM,
then recheck. If the symptom/indication goes away with a known-good ECM/PCM,
replace the original ECM/PCM.
■
NO
-
Repair open in the wire between the ECM/PCM (A6) and PGM-FI main relay 1.■
Turn the ignition switch to LOCK (0).